Tested Ideas-Make Working Ideas
 s

AC High Voltage Oil Test Set

 

Technical Details

 

STEP UP TRANSFORMER : A double wound secondary Epoxy molded Air cooled / oil cooled transformer is used to boost the voltage to required voltage.

VOLTAGE CONTROL : A step less auto-transformer (Variac)  is used for controlling the output from zero to maximum.

INPUT VOLTAGE : 220/230 V single phase
OUTPUT VOLTAGE : 0-50 KV, 0-60 KV, & 0-100 KV

CAPACITY : 0.5 KVA to 1 KVA

METERING : Voltmeter is provided on LT side, cal liberated to indicate the secondary output voltage.

ELECTRODE : As per IS:6792

PROTECTION :

  • The unit consists of  fast acting DC relay provided on HT side to cut off the HT supply in case of flash..

  • Zero start interlocking is provided

TEST CUP :  A test cup of suitable size made of transparent thermoplastic     

CONTROL  : 

  • Potentiometer for output Voltage Setting.

  • Switch for manual and auto use.

  • Push button to increase or decrease voltage manually in case of manual position.

PROTECTION  : The design of the unit is such that it can withstand 20 percent overloading for short durations without any damage. Each unit consists of minimum-maximum range indicator, motor movement control Micro switch at the end of the range and oil Inlet & Outlet valve, oil level indicator, lifting arrangement for whole unit and transformer only, cooling radiator as per the capacity requirement.


OPTIONAL  :
 
Ampere meters, On-Off/switches Fuse, change over switch, under over voltage protection & indication with or without tripping, Arrangement, single phase protection. with or without contractor.